OCS Process Systems
Your cart is empty.
1-800-482-6226
  • Home
  • Products
    • Fittings
      • Weld Fittings
      • Bevel Seat & John Perry Fittings
      • E-Line Fittings
      • Unpolished Tube OD Fittings
      • Clamp Fittings
    • Hoses
      • R-Series: Rubber Hoses
        • RBT Beverage Transfer
        • RCR Crush Resitant
        • RCT Comestible Transfer
        • RDC Discharge
        • RES Premium Suction and Discharge
        • RSD Suction & Discharge
        • RWD Premium Washdown
      • S-Series Silicone Hoses
        • SDB Double Braided Discharge
        • SHF HI-FLEX Wire Reinforced
        • SMD Multi-ply Discharge
        • SMW Multi-ply Wire Reinforced
        • SSD Single Braid Discharge
      • T-Series: Teflon® Hose
        • TRS EPDM Rubber Covered Smooth Bore
        • TCB Steel Braided Convoluted
        • TCP Poly Braided Convoluted
        • TSB Braided Smooth Bore
        • TSC Silicone Covered Smooth Bore
      • P-Series: PVC Hose
        • PBT Braid Reinforced Tubing
        • PBW Suction/Transfer Hose
        • PCT Clear Non-reinforced Tubing
        • PHC Suction/Transport Hose
        • PHH Suction/Transfer Hose
        • PWT Wire Reinforced Tubing
      • I-Series: Industrial Hoses
        • ISH Steam
        • IWD Washdown
    • Maintenance Supplies
      • Sanitary Lubricants
        • Haynes Oil
        • Haynes Spray
        • Haynes Silicone Oil and Spray
        • Haynes Silicone Grease
        • Haynes Lubrifilm Spray
        • Haynes Lubrifilm
        • Haynes Lubrifilm Plus
        • Haynes CIP Film
        • Haynes 500
        • Haynes 500 Plus Grease and Spray
        • Haynes Homogenizer Oil
      • Valve Seal Kits
      • Instrumentation Rebuild Kits and Spare Parts
      • Pump Parts and Kits
        • Tri-Clover Pump Parts and Kits
        • Fristam Pump Parts and Kits
    • Instrumentation
      • Flow
      • Pressure
      • Temperature
      • Level
      • Analytical
    • Tanks
      • Processor Vessels
      • Mixer Vessels
      • Custom Fabrication
      • Storage Tanks
    • Clearance
  • Engineering
    • Process Engineering
    • Plant Drawings
  • Fabrication
    • Welding Capabilities
    • Installation
    • Custom Fabrication
      • Pump Bases and Carts
        • Centrifugal Pump Bases
        • PD Pump Bases
        • Centrifugal Pump Carts
      • Portable Tank Systems
      • Skid Systems
        • CIP Skid Systems
        • HTST Skid System
        • Batching and Blending Skid Systems
      • Holding Tubes
      • Flow Transfer Panels
      • Tote Systems
      • Valve Manifolds
      • Hot Water Sets
    • Welding Supplies
      • Tungsten
      • Welders
      • Plasma Cutters
      • Purge Caps
      • Saw Blocks
  • About
    • Quality Parts and Equipment
    • Support
    • On-Site Service
    • Fabrication
    • Installation
    • Design and Engineering
    • Associations
  • Contact
    • Contact Us
    • Career Opportunities
    • Driving Directions

Flow

  • Products
  •  » Instrumentation
  •  » Flow

Flow

  • Views:

    • original

      Anderson AE Air Eliminator

      from $7,118.48

      Save 13%

      The “AE” air eliminator solves many of the problems associated with air or gas presence in pumped liquids. Line vibration due to 2-phase fl ow, poor fl ow meter measurement accuracy, and product quality issues are a few of the more common negative effects of gas presence in a liquid. As the name suggests, the “AE” series Air Eliminator is designed to remove the air or gas present in these product streams. Designed to be located after the pumping device in a positive pressure line, product enters at a tangent to the wall ofthe vessel, the resultant force stratifi es the incoming product putting the heavier liquidtowards the wall with the lighter aerated product separating towards the center. Thisseparation is then completed by allowing only the liquid at the outer wall to exit the vessel at the bottom located outlet. When a sufficient quantity of air is collected at the center it is automatically vented at the top of the vessel. The fully mechanical design means that no additional control boxes or electrical wiring is needed to operate, simplifying installation and reducing long term ownership cost. Applications for the “AE” can vary from intake receiving systems where the “AE” is used to remove air for proper measurement, to the supply of a filling process for improvement of portion control.

    • original

      Anderson BC-104 Batch Controller

      from $864.85

      Save 13%

      The introduction of the BC-104 brings to Anderson’s offering of superior products an extremely versatile and complete control package. To start, the BC-104 offers all of the capabilities of any stand alone batch controller in a single panel mount device. Then add to this package analog input capability, control inputs, and additional relay and analog outputs that are integrated using an internal programmable logic controller, and you have a device which can satisfy a multitude of custom processing needs. The possibilities range from tank selection or multiple preset capabilities to control of an additive dosing pump or a batch system with automatic supply selection and empty tank level alarms.

    • original

      Anderson HM Turbine Flowmeter

      from $156.46

      Save 13%

      Anderson’s HM-series turbine flowmeter is the solution for applications requiring an economical, accurate flowmeter. Using the proven method of counting the rotation of a turbine within a flowing stream of liquid, the “HM” turbine flowmeter is not merely a modification of an industrial design, but a design that was created specifically for the sanitary food and dairy industry.

    • original

      Anderson HMP Turbine Flowmeter

      from $156.46

      Save 13%

      The “HMP” series turbine flowmeter is suited for applications that require an economical and accurate measurement solution. The “HMP” is designed using the proven method of monitoring the rotation of a turbine rotor in a flowing product stream. This is not a modification of an industrial design but a flowmeter designed specifically for sanitary applications. Understanding the requirements of these applications has produced a flowmeter with superior durability. The all 316L SS construction (including rotor), along with a unique 2-piece housing design eliminates the need for internal locking rings to retain internal components. This makes for a truly cleanable design that also provides exceptional performance. When used with the HTS1000 probe, the non-magnetic sensing of the rotor eliminates drag - present in other magnetically sensed turbines. This lack of drag provides better accuracy and extended operational life. These features, coupled with a durable Rulon® bearing and stainless steel shaft, give the “HMP” the ability to handle difficult process requirements such as steam blowdowns and the need to autoclave without difficulty.

    • original

      Anderson IZMAG Electromagnetic Flowmeter

      $0.00

      The IZMAG is Anderson Instrument Company’s next generation of electromagnetic flow meter. Building on the qualities that have made it’s predecessor, the IZMS meter, the industry standard in accuracy and longevity, the IZMAG incorporates new design and performance features that allow the IZMAG to excel in the most demanding sanitary processing environment.

    • original

      Anderson IZMSG Electromagnetic Flowmeter

      $0.00

      The IZMSG series electromagnetic flowmeter is the ideal choice for conductive fluids and slurries. Measurement accuracy is unaffected by product viscosity, density, temperature, and the presence of suspended particulates and solids. Unique signal processing methods developed from years of experience in the food and dairy industry allows this flowmeter to provide exceptional accuracy and immunity against process and environmental variables.

    • original

      Anderson RZ Sanitary Positive Displacement Flowmeter

      $5,323.85

      Save 13%

      The RZ series positive displacement flowmeter is the solution to applications requiring precision flow measurement from a sanitary design. With an accuracy of ± 0.15% over the operational rate, the RZ is an excellent choice for beverage syrups, clear juices and other products which flow through process lines which are cleaned in place. Designed for use in food processing applications, the RZ is capable of measuring a wide range of products from water to viscous corn syrups.

    • original

      Anderson RZ2AU Utility Positive Displacement Flowmeter

      $4,293.85

      Save 13%

      Anderson's RZU series flowmeter is a utility version of the industry acceptedAccurate RZ series sanitary flowmeter. A lack of polish has made this rugged design suitable for use on corn sweeteners, oils and other products which do not require a 3A approved flowmeter.

Subscribe to OCS Process Systems Subscribe to News

Copyright © 2011 OCS Process Systems