OCS Process Systems
Your cart is empty.
1-800-482-6226
  • Home
  • Products
    • Fittings
      • Weld Fittings
      • Bevel Seat & John Perry Fittings
      • E-Line Fittings
      • Unpolished Tube OD Fittings
      • Clamp Fittings
    • Hoses
      • R-Series: Rubber Hoses
        • RBT Beverage Transfer
        • RCR Crush Resitant
        • RCT Comestible Transfer
        • RDC Discharge
        • RES Premium Suction and Discharge
        • RSD Suction & Discharge
        • RWD Premium Washdown
      • S-Series Silicone Hoses
        • SDB Double Braided Discharge
        • SHF HI-FLEX Wire Reinforced
        • SMD Multi-ply Discharge
        • SMW Multi-ply Wire Reinforced
        • SSD Single Braid Discharge
      • T-Series: Teflon® Hose
        • TRS EPDM Rubber Covered Smooth Bore
        • TCB Steel Braided Convoluted
        • TCP Poly Braided Convoluted
        • TSB Braided Smooth Bore
        • TSC Silicone Covered Smooth Bore
      • P-Series: PVC Hose
        • PBT Braid Reinforced Tubing
        • PBW Suction/Transfer Hose
        • PCT Clear Non-reinforced Tubing
        • PHC Suction/Transport Hose
        • PHH Suction/Transfer Hose
        • PWT Wire Reinforced Tubing
      • I-Series: Industrial Hoses
        • ISH Steam
        • IWD Washdown
    • Maintenance Supplies
      • Sanitary Lubricants
        • Haynes Oil
        • Haynes Spray
        • Haynes Silicone Oil and Spray
        • Haynes Silicone Grease
        • Haynes Lubrifilm Spray
        • Haynes Lubrifilm
        • Haynes Lubrifilm Plus
        • Haynes CIP Film
        • Haynes 500
        • Haynes 500 Plus Grease and Spray
        • Haynes Homogenizer Oil
      • Pump Parts and Kits
        • Fristam
        • Tri-Clover
      • Valve Seal Kits
      • Gaskets and O-rings
    • Instrumentation
      • Flow
      • Pressure
      • Level
      • Analytical
    • Tanks
      • Processor Vessels
      • Mixer Vessels
      • Custom Fabrication
      • Storage Tanks
    • Clearance
  • Engineering
    • Process Engineering
    • Plant Drawings
  • Fabrication
    • Welding Capabilities
    • Installation
    • Custom Fabrication
      • Pump Bases and Carts
        • Centrifugal Pump Bases
        • PD Pump Bases
        • Centrifugal Pump Carts
      • Portable Tank Systems
      • Skid Systems
        • CIP Skid Systems
        • HTST Skid System
        • Batching and Blending Skid Systems
      • Holding Tubes
      • Flow Transfer Panels
      • Tote Systems
      • Valve Manifolds
      • Hot Water Sets
    • Welding Supplies
      • Tungsten
      • Welders
      • Plasma Cutters
      • Purge Caps
      • Saw Blocks
  • About
    • Quality Parts and Equipment
    • Support
    • On-Site Service
    • Fabrication
    • Installation
    • Design and Engineering
    • Associations
  • Contact
    • Contact Us
    • Career Opportunities
    • Driving Directions

Anderson Model HC1 Electrodeless Conductivity Sensors

  • Products
  •  » Anayltical
  •  » Anderson Model HC1 Electrodeless Conductivity Sensors
  • Screen shot 2011-04-26 at 11.28.13 AM.png
  • Screen shot 2011-04-26 at 11.29.14 AM.png
  • original
  • original

Anderson Model HC1 Electrodeless Conductivity Sensors

Anderson’s Model HC1 Electrodeless Conductivity Sensors are rugged, nonfouling sensors designed for cleaning solutions with conductivity ranges from 0-200 up to 0-2,000,000 microSiemens/cm and temperature compensated over a range of 0° and 200°C. Because these sensors are electrodeless and PFA Teflon® coated, there is no instance of polarization, process coating or contamination. For greatest performance accuracy, the HC1 can be installed in a standard 2-1/2" x 2" or 3" x 2" short outlet reducing tee, or can be ordered with our 2" x 2" special Inductive Conductivity Sensor sanitary tee.

$570.00 — $2,040.00

$500.12 — $1,789.90

You save $69.88 — $250.10 (12%)!

Used in conjunction with our inductive conductivity sensors, the DA1 is Anderson’s panel-mount, 1/4 DIN Electrodeless Conductivity Analyzer specifically designed for CIP systems within the dairy, fluid food, beverage and/or biopharmaceutical markets. Alternatively, users may specify Anderson’s DA2 conductivity transmitter. With an operator interface identical to that of the Analyzer, the NEMA 4X enclosed transmitter may be panel, wall, pipe or integral sensor mounted. Detailed specifications and ordering information can be found on the reverse. For more information, visit our website, or contact our Customer Service Department at 1-800-833-0081.

• NEMA 4X stainless steel sensor housing
• Electrodeless design eliminates polarization and electrode coating problems
• PFA Teflon®-coated probe operates at temperatures up to 392°F or 200°C
• Wide measuring range from 0-200 up to 0 – 2,000,000 microSiemens/cm
• NEMA 4X analyzer allows multiple measurements along with built-in concentration tables viewable via a clear back-lit LCD display
• 3-A compliant; Third party verified in accordance with standard 74-02 2-1/2″ x 2″ or 3″ x 2″ short outlet reducing tee, or can be ordered with our 2″ x 2″ special Inductive Conductivity Sensor sanitary tee.

Operational (HC1 Sensor):

Wetted Materials: PFA Teflon® (Complies with 3A)
Operating Temperature Range: 14° to 392°F (-10° to 200°C)
Maximum Flow Rate: 10ft. (3m) per sec.
Measuring Range: From 0-200 to 0-2,000,000 microSiemens/cm
Temperature Compensator: Pt 1000 RTD
Sensor Cable: 5-conductor (plus two isolated shields) cable with Teflon®-coated jacket; rated to 392°F (200°C); 20 ft. (6m) long
Pressure Temperature Limits: 200 psi at 392°F
Mounting: 2″ Tri-Clamp® process connection for mounting in: 2″ x 2″ special tee (73223-A0001) 2-1/2″ x 2″ short outlet reducing tee 3″ x 2″ short outlet reducing tee
Wiring Style: Sealed cable with Strain Relief, or Sealed cable with male 1/2″ NPT & Strain Relief
Operational (DA1 Analyzer and DA2 Transmitter):

Display: Two-line by 16 character LCD
Measurement: Selectable Ranges
• Conductivity: μS/cm: 0-200.0 or 0-2000
• mS/cm: 0-2.000, 0-20.00, 0-200.0 or 0-2000
• S/cm: 0-2.000
• % Concentration: 0-99.99% or 0-200%
• TDS: 0-9999 ppm
• Temperature: -4 to 392°F (-20 to 200°C)
• Analog Outputs: 0.00-20.00 mA or 4.00-20.00mA
Ambient Conditions: -4 to 140°F (-20 to 60°C); 0-95% relative humidity, non-condensing
Temperature Compensation: Automatic from 14.0° to 392°F (-10°C to 200°C), with selection for Pt 1000 Ohm RTD temperature element or manually fixed at a user selected temperature
Memory Backup (non-volatile): All settings retained indefinitely in EEPROM
Performance (DA1 Analyzer):

Accuracy: ± 0.5% of span
Sensitivity: ± 0.2% of span per 24 hours, non-cumulative
Repeatability: ± 0.1% of span or better
Temperature Drift: Zero and span: less than 0.02% of span per °C
Mechanical (DA1 Analyzer):

Panel Mount: 1/4 DIN, polycarbonate with NEMA 4X (IP65) front panel; hardware included for panel mounting
Wall Mount (optional): 7.5″w X 7.5″h X 6.22″d (191mm X191mm X 158mm) fiberglass reinforced polyester with mounting flange and NEMA 4X, (IP65) rating
Electrical (DA1 Analyzer):

Operating Voltage: 90-130 VAC, 50/60 Hz (10 VA max.) or 190-260VAC, 50/60 Hz (10 VA max.)
Outputs (Relay): Two (2) electromechanical relays; SPDT (Form C) contacts; UL rated 5A 115/230 VAC, 5A @30 VDC resistive
Outputs (Analog): Two (2) isolated 0/4-20mA outputs; each with 0.004 mA (12 bit) resolution and capability to drive up to 600 Ohm loads
Performance (DA2 Transmitter):

Accuracy: ± 0.1% of span
Sensitivity: ± 0.05% of span
Repeatability: ± 0.05% of span
Temperature Drift: Zero and span: ± 0.02% of span per °C
Response Time: 1-60 sec. to 90% of value upon step change (with sensor filter setting of zero)
Mechanical (DA2 Transmitter):

General: Polycarbonate; NEMA 4X (IP65) general purpose; choice of panel or wall/pipe/integral mounting hardware
Panel Mount: 3.75″w X 3.75″h X 0.75″d (95mm X 95mm X 19mm)
Wall /Pipe/Integral: 3.75″w X 3.75″h X 2.32″d (95mm X95mm X 60mm)
Electrical (DA2 Transmitter):

Operating Power (Class 2 Power Suply)
• Two-wire hookup: 16-30 VDC
• Three-wire hookup: 14-30 VDC
• Four-wire hookup 12-30 VDC
Output (Analog) One (1) isolated 0/4-20mA output; with 0.004 ma (12 bit) resolution

Subscribe to OCS Process Systems Subscribe to News

Copyright © 2011 OCS Process Systems