Anderson IZMAG Electromagnetic Flowmeter
Anderson IZMAG Electromagnetic Flowmeter
The IZMAG is Anderson Instrument Company’s next generation of electromagnetic flow meter. Building on the qualities that have made it’s predecessor, the IZMS meter, the industry standard in accuracy and longevity, the IZMAG incorporates new design and performance features that allow the IZMAG to excel in the most demanding sanitary processing environment.
$3,375.00
$2,933.55
You save $441.45 (13%)!
From the outside, one will recognize that a compact, all stainless steel housing now provides the highest level of protection from the cleaning chemicals and environmental extremes present in food processing facilities. A standard backlit graphic display provides the metering information not only as numbers and text but also has the ability to display images. By using images along with text a more intuitive feel to navigation is achieved making the programming experience quicker and simpler. On the inside a PFA liner offers increases in pressure, temperature and vacuum capability. This new liner gives the IZMAG the ability to satisfy an expanded list of high temperature
and aseptic applications .
In addition to the other features the flow meter has a compact overall size allowing installation into tight fitting applications without a sacrifice in measurement performance.
• ±.20% accuracy
• Compact design fits challenging applications
• Stainless steel housing suitable for all processing environments
• 3-A compliant; Third party verified in accordance with standard 28-04
Applications
• Milk
• Cream
• Beer
• Tomato Paste
• Sauces
• Molasses
• Yogurt
• Slurries
• Concentrates
• Cleaning solutions
- Performance:
Accuracy: ± .20% of rate*
Size Operational Flow Range
gal/min ltr/min
15 0.3 – 30 1.17 – 11.7
25 0.8 – 80 3.0 – 300
32 1.3 – 130 5.0 – 500
50 3 – 300 11.7 – 1166
65 5.2 – 525 20 – 2000
80 8 – 800 30 – 3000
100 12 – 1200 46 – 4667
* ± 1 mm/sec- Operating / Environmental:
Temperature Limits: 32-212°F (0-100°C) Process
32-265°F (0-165°C)
for 30 min. CIP
Ambient Temperature: DC -12 – 130°F(-25-55°C)
AC -12 – 120°F(-25-45°C)
Pressure Rating: 1.4-145 psi abs.
.1 – 11 bar abs.
Product Requirements: 5 μS min. conductivity
Approvals: ETL, CE, 3-A- Materials / Construction:
Product Contact Surfaces: PFA 316L SS, EPDM
Housing: 304 SS
Enclosure Rating: IP 67
Process Connection Type: Tri-clamp®, Cherry I-line- Electrical / Power / Signal:
Power Requirement: 9-32 VDC 7W/V.A.
100-240 VAC 50-60hz
-15% / + 10% 7W/V.A.
Signal Output: (2) digital pulse output
24VDC @20 mA
(1) digital status output
24VDC @20 mA
(1) 4-20mA passive/active
Optional 2nd 4-20mA w/Hart (passive)
Control Input: (1) 9-32 VDC R<3.2kohms
Connections: (3) M16 ports with cord grips and ½” conduit adapters
Display: Graphic LCD
46 X23mm illuminated
Communications: Hart ver. 6, CS3 BUS